M 2 6 1 1 T FUJITSU

Your #1 Source For Out Of Production, Obsolete, And Hard To Find Hard Drives
CLICK ON THE LOGO ABOVE TO CHECK PRICE AND AVAIABILITY OF THIS DRIVE.
This information is provided as-is for free and Discount Computer Peripherals, Inc. shall not be held liable for any errors or omissions
.
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 1334| 667| |
Capacity form/unform 45/ MB Heads 2| 4| |
Seek time / track 25.0/10.0 ms Sector/track 33| 33| |
Controller IDE / AT Precompensation
Cache/Buffer 64 KB LOOK-AHEAD Landing Zone
Data transfer rate 1.250 MB/S int Bytes/Sector 512
7.400 MB/S ext
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 45 | -40 60
Power: sleep W Humidity % 20 80 | 5 95
standby 2.5 W Altitude km -0.060 3.000| 12.000
idle W Shock g 5 | 50
seek 5.5 W Rotation RPM 3490
read/write W Acoustic dBA 40
spin-up W ECC Bit 32,56
MTBF h 50000
Warranty Month
Lift/Lock/Park YES Certificates
**********************************************************************
L A Y O U T
**********************************************************************
FUJITSU M2611T/M2611T#D OEM MANUAL 41FH5041E-02 / 41FH5059E-01
Part number B03B-7065-B301A
+---------------------------------------------------------+
| |XX Power
| |XX CN6
| |
| CNH-1 |XX
| 12--+ |XX
| | | |XX
| | | |XX
| | | |XX
| | | |XX
| | | |XX
| | | |XX
| 1--+ |XX
| CNH-3 (Option) 9--+ |XX
| 1-------6 | | |xx
| +-------+ | |CNH-2 |XX
| | | |XX Power
| 1--+ |XX CN2
+---------------------------------------------------------+
Part number B03B-7065-B301A#D
+---------------------------------------------------------+
| |XX Power
| |XX CN6
| |
| |XX
| |XX 40 pin
| +-+ SW2 |XX
| +-+ 6+-----------------------+1 |XX
| LED | | |XX
| +-----------------------+ |XX
| |XX
| +--------------+ |XX
| | | |XX
| 4+--------------+1 |XX
| SW1 |xx
| |XX
| |XX Power
| |XX CN2
+---------------------------------------------------------+
**********************************************************************
J U M P E R S
**********************************************************************
FUJITSU M2611T/M2611T#D OEM MANUAL 41FH5041E-02 / 41FH5059E-01
Switches locations
==================
x = Jumpers are set from factory
There are two versions: M2611T part number B03B-7065-B301A
M2611T#D B03B-7065-B301A#D
M2611T only
----------------------------------------------------------------
CNH-1 Slave present mode / Active mode
---------------------------------------
x 1- 2 CLOSE Active mode
2- 3 OPEN
1- 2 OPEN Slave present mode
2- 3 CLOSE
This operation is to set the slave present or active mode of M261xT.
CNH-1 I/O channel ready (IOCHRDY)
----------------------------------
4- 5 CLOSE Pin 27 = IOCHRDY
5- 6 OPEN
4- 5 OPEN PIN 27 = Reserved
x 5- 6 CLOSE
When the data transfer rate of the host becomes very high (near
7.4MB/s or more), the M261xT must provide wait state to synchronize
data transfer. This setting is used to output IOCHRDY to pin 27 of
the host interface.
CNH-1 1-drive/2-drive system
-----------------------------
7- 8 CLOSE 2-drive system
8- 9 OPEN
7- 8 OPEN 1-drive system
x 8- 9 CLOSE
CNH-1 IRQ14/RSVD switch
------------------------
10-11 CLOSE After exchange Pin 29 = IRQ14
11-12 OPEN Pin 31 = Reserved
10-11 OPEN Normal status Pin 29 = Reserved
x 11-12 CLOSE Pin 31 = IRQ14
This operation is to exchange settings of pin 29 and 31 to eliminate
cross talk influence in the host interface cable.
CNH-2 MASTER/SLAVE drive system
--------------------------------
1- 2 CLOSE SLAVE drive
4- 5 OPEN
1- 2 OPEN MASTER drive
x 4- 5 CLOSE
CNH-2 ECC bytes
----------------
7- 8 CLOSE 4 bytes
8- 9 OPEN
7- 8 OPEN 7 bytes
x 8- 9 CLOSE
In 4Byte ECC mode, the READ LONG/WRITE LONG command can be executed
successfully only under the following sequence:
READ LONG -> WRITE LONG
CNH-3 Write protect (provided as an option)
--------------------------------------------
1- 2 CLOSE Write protected
2- 3 OPEN
1- 2 OPEN Write enabled
x 2- 3 CLOSE
M2611T#D only
----------------------------------------------------------------
SW1 IRQ14/RSVD switch
------------------------
1 OFF After exchange Pin 29 = IRQ14
2 ON Pin 31 = Reserved
1 ON Normal status Pin 29 = Reserved
x 2 OFF Pin 31 = IRQ14
This operation is to exchange settings of pin 29 and 31 to eliminate
cross talk influence in the host interface cable.
SW1 Slave present mode / Active mode
---------------------------------------
x 3 OFF Active mode
4 ON
3 ON Slave present mode
4 OFF
This plug should be set in Active mode on daisy-chained connection
of both M261xT (M261xET).
The logical information of setting plugs is subject to change without
prior notice.
SW2 MASTER/SLAVE drive system
--------------------------------
1 OFF SLAVE side of 2-drive system
2 ON
1 ON MASTER drive
x 2 OFF
SW2 1-drive/2-drive system
-----------------------------
3 ON 2-drive system
x 3 OFF 1-drive system
SW2 Write protect (provided as an option)
------------------------------------------
4 ON Write protected
x 4 OFF Write enabled
SW2 I/O channel ready (IOCHRDY)
--------------------------------
5 ON Pin 27 = IOCHRDY
x 5 OFF Pin 27 = Reserved
When the data transfer rate of the host becomes very high (near
7.4MB/s or more), the M261xT must provide wait state to synchronize
data transfer. This setting is used to output IOCHRDY to pin 27 of
the host interface.
SW2 ECC bytes
--------------
6 ON 4 bytes
x 6 OFF 7 bytes
In 4Byte ECC mode, the READ LONG/WRITE LONG command can be executed
successfully only under the following conditions:
-> READ LONG -> WRITE LONG sequence is only acceptable
-> The sector number of READ LONG and WRITE LONG must be the same
-> The number of sector on WRTIE LONG must be the same one that
host issued to the drive on READ LONG.
**********************************************************************
I N S T A L L
**********************************************************************
FUJITSU M2611T/M2612T/M2613T/M2614T OEM MANUAL 41FH5041E-02
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+---------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+--+---------------+---+ | | | | | |
+----------------------+ | | | | | |
| | | | | |
X X | | | | | |
+------X-------X-------+ | | | | | |
+--+-----X---X-----+---+ | +-----+ +-----+ |
| X X | +--+ +--+
| X X |
+--X--------X---+
X X
If the drive is installed in any of the above three installation
directions, the level deviation must not exceed 5*.
Never install PCA to the top!
Ambient temperature
-------------------
The ambient temperature is measured at a point 3cm from the drive
when it is installed in a cabinet.
Set the air flow so that this temperature does not exceed 45*C.
The standard base surface temperature is 58*C or less. Air circula-
ting in the cabinet should cool the PCA side especially.
Cable requirements
------------------
The cable of twisted pairs and neighboring line separated individu-
ally is not allowed to use for the host interface cable. It is be-
cause cross talk is generated when the data transfer rate becomes
very high.
Cable length: 0.5m Max.
**********************************************************************
F E A T U R E S
**********************************************************************
FUJITSU M2611T/M2612T/M2613T/M2614T OEM MANUAL 41FH5041E-02
Buffer
======
The M261xT supports a look-ahead cache to increase system throughput.
The M261xT uses 56KB of the cache to read and 6KB to write and a 2KB
area to download sequencer programs.
Data transfer rate
==================
A maximum transfer rate of 7.4MB/s is accomplished with a 30MHz clock
signal and high-speed buffer management. When the data transfer rate
becomes near 7.4MB/s or more, the host must recieve IOCHRDY signal
and maintain the transfer synchronisation by setting a wait state.
Power save mode
===============
When the M261xT will not be operated for a long time, power consump-
tion can be reduced by using the power save mode.
The M261xT supports two power modes which are selectable by the POWER
command: idle mode and power save mode. In the power save mode, power
is supplied only to the controller circuit, the spindle motor circuit
and the drive control IC. Power to the other components is shut off
by the power FET. Thus low power consumption is accomplished. In this
mode, the spindle keeps rotation for hot restart.
Actuator lock mechanism
=======================
When the M261xT is not in service, the actuator lock mechanism locks
the head positioning arm to protect it.
Start and stop time
===================
Start time (time from when power is turned on until the IDD is ready)
is 15 seconds or less, and stop time (time to completely stop when
power is turned off) is 25 seconds or less.
Power on/off sequence
=====================
The +5V and +12V power supplies are monitored by the voltage check
circuit. The circuit allows a write current to flow only when the
both voltages are normal. Accordingly, no power sequence is required.
This is for protection of the content of the medium.
AC line noise
=============
To eliminate AC line noise, a noise filter of the specifications
given below should be incorporated in the AC input terminal of the
drive power supply.
Attenuation characteristics: 40 dB or greater at 10MHz
Circuit configuration: T type
Mean Time Between Failures (MTBF)
=================================
The MTBF is defined as follows:
Operating time
MTBF = -----------------------------------------
Number of equipment failures in the field
Operating time is the total time duration during which the power is
on, excluding preventive maintenance.
Failure of the equipment means a failure that requires repair, ad-
justment, or replacement, excluding preventive maintenance. Errors
by the operator, failures due to power failures, controller faults,
cable faults, bad environmental conditions, or other failures not
caused by the equipment itself are not included.
The IDD is designed for an MTBF of 50.000 hours.
Mean Time To Repair (MTTR)
==========================
MTTR is the average time taken by a well-trained service engineer to
diagnose and repair a unit malfunction. The IDD is designed for a
MTTR of 30 minutes or less.
Service life
============
Overhaul of the drive is not required for the first five years.
Data protection against power failure
=====================================
Integrity of the data on the disk is guaranteed against all forms of
abnormal DC power except a power failure during writing.
Media Defect
============
When a physical track contains two ore more bad sectors, all sectors
in the track are given BAD flags in formatting before the M261xT is
shipped.
As regards media defect, it defines with number of bad tracks as
follows. (provided that CYL0, HD0 is defect free)
Number of bad tracks per drive: max. 12 M2611T
max. 24 M2612T
max. 36 M2613T
max. 48 M2614T
Drive BIOS specification
========================
The BIOS specification of the host must meet that of the M261xT in
the number of cylinders, number of heads and sectors per track in
order to make best use of the IDD. The BIOS specification of the IDD
is specified by SET PARAMETERS. The IDD can be used if an appropriate
BIOS specification from the existing drive type table in the host is
selected within the capacity of the IDD. In this case the IDD can be
operated within the limits of the capacity which is selected by the
drive type.
**********************************************************************
G E N E R A L
**********************************************************************
FUJITSU => GDT
Tips & Hints about ICP controllers and other peripherals
========================================================
Tagged queues and Fujitsu M 26xx harddisks
------------------------------------------
Fujitsu Harddisks of the M26XX series do not support the SCSI-II
feature tagged queues. You should disable this feature in the
initialize disks menue of the GDTSetup program. An inquiry command
shows, that the harddisk supports tagged queues (this is why you can
enable it in the GDTSetup) but this is not true as stated by Fujitsu
Germany.