M 2 2 6 3 E FUJITSU

Your #1 Source For Out Of Production, Obsolete, And Hard To Find Hard Drives
CLICK ON THE LOGO ABOVE TO CHECK PRICE AND AVAIABILITY OF THIS DRIVE.
This information is provided as-is for free and Discount Computer Peripherals, Inc. shall not be held liable for any errors or omissions
.
Native| Translation
------+-----+-----+-----
Form 5.25"/FH Cylinders 1658| | |
Capacity form/unform 611/ 778 MB Heads 15| | |
Seek time / track 16.0/ 4.0 ms Sector/track 53| | |
Controller ESDI Precompensation 65535
Cache/Buffer KB Landing Zone
Data transfer rate 1.875 MB/S int Bytes/Sector 512
5.000 MB/S ext
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 45 | -40 60
Power: sleep W Humidity % 20 80 | 5 95
standby W Altitude km 3.000| 12.000
idle W Shock g 2 | 20
seek W Rotation RPM 3600
read/write 28.0 W Acoustic dBA
spin-up W ECC Bit
MTBF h 30000
Warranty Month
Lift/Lock/Park YES Certificates
**********************************************************************
L A Y O U T
**********************************************************************
FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02
+---------------------------------------------------------+
| 16+----+2 |XX 20 Pin
| 15+CNH7+1 |XX
| +---+CN4 16+----+2 |XX
| +---+CN5 15+CNH6+1 15+-+16 |XX
| +---+CN6 | | +--------+ |
| +---+ CNH5| +Terminat+ |XX 34 Pin
| 1+-+2 |XX
| 15+-+16 |XX
| CNH2| |XX
| | | |XX
| 16+----+2 1+-+2 |XX
| 16+----+2 15+CNH1+1 |XX
| 15+CNH3+1 1+-+2|XX
| CN7 | |
| | | |
| 16+----+2 3210 5+-+6|XX Power
| 15+CNH4+1 **** Fault Lamp |XX
+---------------------------------------------------------+
**********************************************************************
J U M P E R S
**********************************************************************
FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02
Fault Lamps and Setting Plugs
=============================
Selectable by user side: Terminator
CNH5, CNH6, CNH7
Fixed at factory: CN4, CN5, CN6, CN7
CNH1, CNH2, CNH3, CNH4
Jumper Settings
===============
x = Jumpers are set from factory
CNH3 Offtrack Compensation
---------------------------
15-16 OPEN Enable
CLOSE Disable
CNH5 READY LED lighting conditions
-----------------------------------
x 15-16 OPEN Drive select signal not gated
CLOSE Drive select signal gated
CNH6 Drive select
------------------
Drive 1 2 3 4 5 6 7
------+-----+-----+-----+-----+-----+-----+-----
x 1- 2 |CLOSE|OPEN |OPEN |OPEN |OPEN |OPEN |OPEN
3- 4 |OPEN |CLOSE|OPEN |OPEN |OPEN |OPEN |OPEN
5- 6 |OPEN |OPEN |CLOSE|OPEN |OPEN |OPEN |OPEN
7- 8 |OPEN |OPEN |OPEN |CLOSE|OPEN |OPEN |OPEN
9-10 |OPEN |OPEN |OPEN |OPEN |CLOSE|OPEN |OPEN
11-12 |OPEN |OPEN |OPEN |OPEN |OPEN |CLOSE|OPEN
13-14 |OPEN |OPEN |OPEN |OPEN |OPEN |OPEN |CLOSE
CNH6 Signal gate or not (Select signal)
----------------------------------------
x 15-16 OPEN Gate (daisy)
CLOSE No gate (radial)
When the pins are shorted, the drive output signals are always
enabled, regardless of Drive Select signal. Without a jumper
here, the output signals are enabled only when the drive is
selected.
CNH7 Motor start control from interface
----------------------------------------
1- 2 OPEN Yes
x CLOSE No
CNH7 Device Type selection (model specific)
--------------------------------------------
Device M2261 M2262 M2263
------+-----+-----+-----
3- 4 |OPEN |OPEN |CLOSE
5- 6 |OPEN |CLOSE|OPEN
CNH7 Sector setting
--------------------
Sectors/Track 24 27 28 48 51 53 54 96
Bytes/Sector |1304 |1159 |1117 | 652 | 613 | 590 | 579 | 362
-------------+-----+-----+-----+-----+-----+-----+-----+-----
x 7- 8 |OPEN |OPEN |OPEN |OPEN |CLOSE|CLOSE|CLOSE|CLOSE
x 9-10 |OPEN |OPEN |CLOSE|CLOSE|OPEN |OPEN |CLOSE|CLOSE
x 11-12 |OPEN |CLOSE|OPEN |CLOSE|OPEN |CLOSE|OPEN |CLOSE
Valid only in hard sector mode
CNH7 Sector mode setting
-------------------------
13- 14 OPEN Drive hard sector
CLOSE Controller soft sector
CNH7 Power ON Reset Condition
------------------------------
x 15- 16 OPEN ATTENTION signal and bit 8 of Status byte are
set at the READY state just after power-on.
CLOSE ATTENTION signal and bit 8 of Status byte are
not set at the READY state just after power-on.
Fault lamps
===========
Drive fault states are displayed by the fault lamps (0,1,2,3)
Fault lamp| Drive State
3 2 1 0 |
----------+--------------------------------------------------
x x x o | Spindle motor rotation less than 90% of standard
x x o x | VCM over current
x x o o | Initial seek time out
x o x x | Write command during seek operation
x o x o | +12V/+5V less than 80% of standard
x o o x | Off track during Write operation
x o o o | Write Echo check
o x x x | Two or more head ICs selected during
| operation
o x x o | Seek time out
o x o x | Guard band detection during Seek operation
o x o o | Guard band detection during linear mode
o o x x | Overshoot check
o o x o | Seek command without ONTRACK signal true
o o o x | Head load signal lost after READY
o o o o | Read and Write commands simultaneously issued or
| other miscellaneous faults
x x x * | Invalid or unimplemented command fault
x x * x | Interface time out fault
x x * * | Command data parity fault
x * x x | Spindle sync error
o = On x = Off * = Blinking
**********************************************************************
I N S T A L L
**********************************************************************
FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02
Notes on installation
=====================
Installation direction
----------------------
horizontally vertically
+-----------------+ +--+ +--+
| | | +-----+ +-----+ |
| | | | | | | |
+-+-----------------+-+ | | | | | |
+---------------------+ | | | | | |
| | | | | |
x x | | | | | |
+------x------x-------+ | +-----+ +-----+ |
+-+------x--x-------+-+ +--+ +--+
| xx |
| x x |
+---x--------x----+
x x
There are three possible installation directions, and the mounting
angle must be 5* from the horizontal.
Ambient temperature
-------------------
The operating temperature range of the drive is specified at a dis-
tance of 3 cm from the drive. Note, temperature specifications are
for the outside air surrounding the drive.
Multi-drive connection
----------------------
In serial mode, up to 7 drives can be connected. The termination of
the control signals must be performed only at the last drive. The
terminator must be removed from all but the last drive.
**********************************************************************
F E A T U R E S
**********************************************************************
FUJITSU M2261E/2262E/2263E OEM MANUAL 41FH5031E-02
Defect list
===========
When the unit leaves the factory, a printed media defect list for
each drive is sent with it. This information is also written on the
media.
Cylinder 0, Head 0 and 1 are defect free!