C F S - 2 7 0 A C A B O CONNER

Your #1 Source For Out Of Production, Obsolete, And Hard To Find Hard Drives
CLICK ON THE LOGO ABOVE TO CHECK PRICE AND AVAIABILITY OF THIS DRIVE.
This information is provided as-is for free and Discount Computer Peripherals, Inc. shall not be held liable for any errors or omissions
.
Native| Translation
------+-----+-----+-----
Form 3.5"/SLIMLINE Cylinders 2595| 525| |
Capacity form/unform 270/ MB Heads 2| 16| |
Seek time / track 15.0/ 3.0 ms Sector/track | 63| |
Controller IDE / ATA2 FAST/ENHA Precompensation
Cache/Buffer 32 KB SEGMENTED Landing Zone
Data transfer rate MB/S int Bytes/Sector 512
13.000 MB/S ext
Recording method RLL 1/7 operating | non-operating
-------------+--------------
Supply voltage 5/12 V Temperature *C 5 55 | -40 60
Power: sleep 1.0 W Humidity % 8 80 | 8 80
standby 1.0 W Altitude km -0.061 3.048| -0.061 12.192
idle 3.0 W Shock g 5 | 75
seek 4.5 W Rotation RPM 3400
read/write 4.0 W Acoustic dBA 34
spin-up W ECC Bit
MTBF h 250000
Warranty Month
Lift/Lock/Park YES Certificates
**********************************************************************
L A Y O U T
**********************************************************************
CONNER CFS-270A QUICK REFERENCE GUIDE REV. C, 12/1994
+---------------------------------------------------------+
| |XXI
| |XXN
| |XXT 40PIN
| |XXE
| |XXR
| |XXF
| |XXA
| |XXC
| |XXE
| |XX
| |XX
++-+C/D |
++ | |XX J2
++ |C/S |xx Power
++ | |XX
++-+ |XX J6
+---------------------------------------------------------+ Power
**********************************************************************
J U M P E R S
**********************************************************************
CONNER CFS-270A QUICK REFERENCE GUIDE REV. C, 12/1994
Jumper Setting
==============
The C/D jumper is used to determine whether the drive is a master
(drive C) or a slave (drive D). The drive is configured as a master,
when jumpered, and a slave when not jumpered.
Master/Standalone
-----------------
C/D A/C CS
x o o C/D CLOSED
X o o
Slave
-----
C/D A/C CS
o o o All OPEN
o o o
Cable Select Master or Slave
----------------------------
C/D A/C CS
o o x CS CLOSED
o o X
**********************************************************************
I N S T A L L
**********************************************************************
CONNER CFS-270A QUICK REFERENCE GUIDE REV. C, 12/1994
Notes on Installation
=====================
J6 Standard 4-pin Power Connector
---------------------------------
+-----------------------
| +-----J6-----+ +---- pin 1 +12V
| | 1 2 3 4 | | 1 pin 2 GND
| +------------+ +-- pin 3 GND
+------------------ pin 4 +5V
J2 Optional 3-pin Power Connector
---------------------------------
+------------------------------
| +-----J6-----+ +--J2---+ +--- pin 1 +5 V
| | 1 2 3 4 | | 1 2 3 | | 1 pin 2 +12V
| +------------+ +-------+ +---- pin 3 GND
+----------------------------------
Mounting Holes
--------------
Side: 6-32 UNC-2B .16 max. insertion
Bottom: 6-32 UNC-2B .22 max. insertion